Description of the method:
The test consists in filtering the oil sample through a membrane with a porosity of 0,8 µm and noting the filtering time for specific volumes.
Grade I filterability – for volume.
Filterability level II – for the flow rate
Interpretation of the results:
For results above 50, the oil is filterable, the closer to 100 the better. Below 50, the oil is considered nonflowable. For a passed stage I, no problems with filtration are expected with the assumption of filtration without the use of fine filters. For a passed stage II, no problems are expected even when using absolute filters, below 5 µm.