Description of the method:
Coulometric method based on the reaction of iodine with water present in the sample. The water content is proportional to the amount of iodine consumed during the titration reaction. At the equivalence point, an excess of iodine appears, causing a drop in voltage. The water content in the tested sample is calculated based on the amount of current needed to generate iodine during the reaction.
Interpretation of the results:
Water present in transformer oil deteriorates its insulating properties and adversely affects the condition of paper insulation, accelerating its degradation. The solubility of water in oil is temperature-dependent. At high temperatures, the solubility of water in oil increases, while at low temperatures, the insulating paper absorbs water from the oil.